In China, there are only six plants which have the port special-purpose bulk cement equipment (the cement plants are on the port) of their own, our plant is just one of those plants. We export 5 million MTS per year. The most important thing is our products have passed the ISO international authentication. Our loading port can load 700 MTS per hour (in bulk). We also own our specialized anchorage site. Our port (LOA 200M, Draft 10.5~13M) can berth the ship with tonnage between 10,000 ~60,000tons.
As we are an export firm subordinated to a cement plant, we have the superiority to offer you the lowest price in this line. We can supply Clinker and ASTM C90-97 TYPE I cement and GB175-2007 P.C 32.5(R) & P.O 42.5(R) & P.O 52.5(R) cement of any kind!

The details of the Rizhao port:

1) The work time is 24 hours without rest.
2) No holiday,no weekend if vessel coming.
3) The extend of between the two berth is 40-50 meters.
4) The way of loading and discharging are by gantry crane, auto crane, tabulate auto or with pump( for bulk).
5) The normal load rate is 10,000~
18,000mt/wwd.
6) The sea port usually wouldn't like to accept the double broads vessel.


CEMENT CATEGORY
  • Product:Composite Portland Cement GB175-2007 P.C 32.5(R)
  • Origin:China
  • Packing:2 MT Jumbo bags or 50 KG bags + 2 MT Jumbo bags or other
 
  • Product:Ordinary Portland Cement GB175-2007 P.O 42.5(R)
  • Origin:China
  • Packing:In bulk or 2 MT Jumbo bags or 50 KG bags + 2 MT Jumbo bags or other
 
  • Product:Ordinary Portland Cement GB175-2007 P.O 52.5(R)
  • Origin:China
  • Packing:In bulk or 2 MT Jumbo bags or 50 KG bags + 2 MT Jumbo bags or other
 
  • Product:OPC ASTM C150-97 TYPE I/II
  • Origin:China
  • Packing:In bulk
 
  • Product:Cement Clinker
  • Origin:China
  • Packing:In bulk



SPECIFICATION FOR CEMENT
OPC ASTM C150-97 TYPE I/II & GB175-2007 P.O52.5R & 52.5 & P.O42.5R & 42.5 & P.C32.5R & 32.5 CEMENT. The eligible rate of leaving factory cement and the eligible rate of margin coefficient have kept 100% twenty-five years in succession. Through ISO9002 quality system certification and product quality certification.
Character Brief Introduction:
All the technological indexes of "1001PP." brand cement overstep the national standard and accord with international advanced level. With their characters of high strength in early period, fast coagulation and hardening, low-alkali, strong resistance to corrosion of acid and alkali, resistance to cold and melt, short period of leaving matrix and high speed construction, they are widely used in industry and civil construction and especially in roads, bridges, ports, water conservancy and underground construction.
Technological Index:
SPECIFICATION FOR CEMENT
ASTM C150-97 TYPE I/II
(ASTM I / II ) Examine data Mandatory Targets Standard
SiO² (%) 20.61 min.20.0 ASTM C114
Al²O³(%) 4.89 max.6.0 ASTM C114
Fe²O³(%) 3.41 max.6.0 ASTM C114
MgO(%) 3.68 max.6.0 ASTM C114
SO³(%) 2.38 max.3.0 ASTM C114
C³A(%) 7.18 max.8.0 ASTM C114
Loss on Ignition(LOI)(%) 1.69 max.3.0 ASTM C114
Insoluble Residue(%) 0.61 max.0.75 ASTM C114
Alkalies(Na²O+0.658K²O) (%) 0.51 max.0.60 ASTM C114
(ASTM I / II )
Blaine m²/kg 347 min.280 ASTM C204
Air Content 7.1 max.12.0 ASTM C185
Vicat(Initial) Set Time 142 min.45 ASTM C191
Vicat(Final) Set Time 195 max.375 ASTM C191
Autoclave Expansion 0.18 max.0.80 ASTM C151
Palse Set Paste 86.0 min.50 ASTM C451
Strength @ 3-day 19.6 min.12.0 ASTM C109/C109M
Strength @ 7-day 25.2 min.19.0 ASTM C109/C109M
SURVEY REPORT GB175-2007 P.O 52.5R
ITEMS Examine data Mandatory Targets Standard
MgO(%) ≤4.0 5.0 GB/T 176-1999
SO3(%) ≤3.0 ≤3.5 GB/T 176-1999
LOI(%) ≤3.0 ≤5.0 GB/T 176-1999
Fineness(80p m residue on sieve)(%) ≤3.0 ≤10.0 GB/T 1345-1991
Setting Time: Initial (min) 60-120 ≥45 GB/T 1346-2001
Setting Time: Final (min) 120-230 ≤600 GB/T 1346-2001
Soundness(pat test) qualified qualified GB/T 1346-2001
Strength (3 day):Bending Strength (Mpa) ≥5.0 ≥5.0 GB/T 17671-1999
Strength (3 day):Compressive Strength(Mpa) ≥29.0 ≥26.0 GB/T 17671-1999
Strength(28 day):Bending Strength (Mpa) ≥7.5 ≥7.0 GB/T 17671-1999
Strength (28 day):Compressive Strength(Mpa) ≥55.0 ≥52.5 GB/T 17671-1999
SURVEY REPORT GB175-2007 P.O 42.5 R
Portland Cement GB175-2007 P.O 42.5 R DATE: 2005.8.1
ITEMS Examine data Mandatory Targets Standard
MgO(%) 3.49 ≤5.0 GB/T 176-1999
SO3(%) 2.48 ≤3.5 GB/T 176-1999
LOI(%) 4.29 ≤5.0 GB/T 176-1999
Fineness(80p m residue on sieve)(%) 4.0 ≤10.0 GB/T 1345-1991
Setting Time:Initial(min) 152 ≥45 GB/T 1346-2001
Setting Time: Final(min) 230 ≤600 GB/T 1346-2001
Soundness(pat test) Qualified Qualified GB/T 1346-2001
Strength (3 day):Bending Strength (Mpa) 5.7 ≥4.0 GB/T 17671-1999
Strength (3 day):Compressive Strength(Mpa) 28.0 ≥21.0 GB/T 17671-1999
Strength (28 day):Bending Strength (Mpa) 8.3 ≥6.5 GB/T 17671-1999
Strength (28 day):Compressive Strength(Mpa) 48.0 ≥42.5 GB/T 17671-1999
P. C 32.5\P. C 32.5R\P. O 42.5\P. O 42.5R
Items/Indexex P.C 32.5 P.C 32.5R P.O 42.5 P.O 42.5R
National standard Internally controlled indexes National standard Internally controlled indexes National standard Internally controlled indexes National standard Internally controlled indexes
Cement MgO(%) ≤5.0 ≤4.0 ≤5.0 ≤4.0 ≤5.0 ≤4.0 ≤5.0 ≤4.0
Cement SO3(%) ≤3.5 ≤3.0 ≤3.5 ≤3.0 ≤3.5 ≤3.0 ≤3.5 ≤3.0
Cement loss
on ignition (%)
≤5.0 ≤4.0 ≤5.0 ≤4.0 ≤5.0 ≤4.0 ≤5.0 ≤4.0
Cement
fineness(%)
≤10.0 ≤6.0 ≤10.0 ≤6.0 ≤10.0 ≤4.0 ≤10.0 ≤4.0
Setting time (min) Initial
setting
time
≥45 ≥60 ≥45 ≥60 ≥45 ≥60 ≥45 ≥60
Final
setting
time
≤600 ≤300 ≤600 ≤300 ≤600 ≤270 ≤600 ≤270
Soundness Qualified Qualified Qualified Qualified Qualified Qualified Qualified Qualified
Strength (MPa) 3-day bending strength ≥2.5 ≥3.5 ≥3.5 ≥4.0 ≥3.5 ≥4.5 ≥4.0 ≥5.0
3-day compressive strength ≥11.0 ≥19.0 ≥16.0 ≥21.0 ≥16.0 ≥25.0 ≥21.0 ≥26.0
28-day bending strength ≥5.5 ≥6.5 ≥5.5 ≥6.5 ≥6.5 ≥7.5 ≥6.5 ≥7.5
28-day compressive strength ≥32.5 ≥38.0 ≥32.5 ≥38.0 ≥42.5 ≥50.0 ≥42.5 ≥50.
Copyright © 2000-2010 Hanker International All rights reserved.
Tel:+0086-633-2201637  2201627  2201617   Fax:+0086-633-2201647
Add:3/F.,Dongwei Edifice,Haibin 2 Road,Rizhao,Shandong,China